Abstract
Objectives The aim of the study was to investigate the kinetic and kinematic changes in the stifle after a tibial plateau levelling osteotomy (TPLO) with a postoperative tibia plateau angle (TPA) of either 6 or 1degrees. Study Design Biomechanical ex vivo study using seven unpaired canine cadaver hindlimbs from adult Retrievers. Hinge plates were applied and a sham TPLO surgery was performed. Motion sensors were fixed to the tibia and the femur for kinematic data acquisition. Pressure mapping sensors were placed between femur and both menisci. Thirty per cent bodyweight was applied to the limbs with the stifle in 135degrees of extension. Each knee was tested with intact cranial cruciate ligament (CCL), deficient CCL, 6 degrees TPLO and 1degree TPLO. Results Transection of the CCL altered kinematics and kinetics. However, comparing the intact with both TPLO set-ups, no changes in kinematics were detected. After 1degree TPLO, a significant reduction in the force acting on both menisci was detected ( p =0.006). Conclusions Tibial plateau levelling osteotomy restores stifle kinematics and meniscal kinetics after transection of the CCL ex vivo . The contact force on both menisci is reduced significantly after TPLO with a TPA of 1degree. Increased stifle flexion might lead to caudal tibial motion.
Dokumententyp: | Zeitschriftenartikel |
---|---|
Fakultät: | Tiermedizin > Zentrum für Klinische Tiermedizin |
Themengebiete: | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin und Gesundheit |
ISSN: | 0932-0814 |
Sprache: | Englisch |
Dokumenten ID: | 101868 |
Datum der Veröffentlichung auf Open Access LMU: | 05. Jun. 2023, 15:38 |
Letzte Änderungen: | 08. Apr. 2024, 14:13 |