Chaloupka, Michael ORCID logoORCID: https://orcid.org/0000-0002-8814-6412; Pyrgidis, Nikolaos; Ebner, Benedikt ORCID logoORCID: https://orcid.org/0000-0003-2126-7305; Volz, Yannic ORCID logoORCID: https://orcid.org/0000-0002-5468-9398; Pfitzinger, Paulo L.; Berg, Elena; Enzinger, Benazir; Atzler, Michael; Ivanova, Troya; Clevert, Dirk‐André; Buchner, Alexander; Stief, Christian G. und Apfelbeck, Maria (2024): Added value of randomised biopsy to multiparametric magnetic resonance imaging‐targeted biopsy of the prostate in a contemporary cohort. In: BJU International [PDF, 188kB]

Abstract

Objective To assess the added value of concurrent systematic randomised ultrasonography-guided biopsy (SBx) to multiparametric magnetic resonance imaging (mpMRI)-targeted biopsy and the additional rate of overdiagnosis of clinically insignificant prostate cancer (ciPCa) by SBx in a large contemporary, real-world cohort.

Patients and Methods A total of 1552 patients with positive mpMRI and consecutive mpMRI-targeted biopsy and SBx were enrolled. Added value and the rate of overdiagnosis by SBx was evaluated. Primary outcome: added value of SBx, defined as detection rate of clinically significant PCa (csPCa; International Society of Urological Pathology [ISUP] Grade ≥2) by SBx, while mpMRI-targeted biopsy was negative or showed ciPCa (ISUP Grade 1). Secondary outcome: rate of overdiagnosis by SBx, defined as detection of ciPCa in patients with negative mpMRI-targeted biopsy and PSA level of <10 ng/mL.

Results Detection rate of csPCa by mpMRI-targeted biopsy and/or SBx was 753/1552 (49%). Added value of SBx was 145/944 (15%). Rate of overdiagnosis by SBx was 146/656 (22%). Added value of SBx did not change when comparing patients with previous prostate biopsy and biopsy naïve patients. In multivariable analysis, a Prostate Imaging-Reporting and Data System (PI-RADS) 4 index lesion (odds ratio [OR] 3.19, 95% confidence interval [CI] 1.66–6.78; P = 0.001), a PI-RADS 5 index lesion (OR 2.89, 95% CI 1.39–6.46; P = 0.006) and age (OR 1.05, 95% CI 1.03–1.08; P < 0.001) were independently associated with added value of SBx.

Conclusions In our real-world analysis, we saw a significant impact on added value and added rate of overdiagnosis by SBx. Subgroup analysis showed no significant decrease of added value in any evaluated risk group. Therefore, we do not endorse omitting concurrent SBx to mpMRI-guided biopsy of the prostate.