Abstract
Hemoperitoneum in cirrhosis is a life-threatening condition that requires emergent evaluation. Contrast-enhanced ultrasound (CEUS) permits multiple dynamic characterizations of abdominal structures through all vascular phases, and contrast extravasation or the presence of microbubbles in the ascites could be a sensitive tool. We reviewed 13 patients with cirrhosis that underwent CEUS due to high suspicion for intra-abdominal bleeding. In 10 cases, CEUS demonstrated extravasation of contrast, including 2 instances where CEUS detected active bleeding despite negative computed tomography. These data support further study of CEUS in direct comparison to other imaging modalities in this clinical context.
Dokumententyp: | Zeitschriftenartikel |
---|---|
Fakultät: | Medizin |
Themengebiete: | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin und Gesundheit |
ISSN: | 0278-4297 |
Sprache: | Englisch |
Dokumenten ID: | 111564 |
Datum der Veröffentlichung auf Open Access LMU: | 02. Apr. 2024, 07:27 |
Letzte Änderungen: | 02. Apr. 2024, 07:27 |