Abstract
Hemoperitoneum in cirrhosis is a life-threatening condition that requires emergent evaluation. Contrast-enhanced ultrasound (CEUS) permits multiple dynamic characterizations of abdominal structures through all vascular phases, and contrast extravasation or the presence of microbubbles in the ascites could be a sensitive tool. We reviewed 13 patients with cirrhosis that underwent CEUS due to high suspicion for intra-abdominal bleeding. In 10 cases, CEUS demonstrated extravasation of contrast, including 2 instances where CEUS detected active bleeding despite negative computed tomography. These data support further study of CEUS in direct comparison to other imaging modalities in this clinical context.
Item Type: | Journal article |
---|---|
Faculties: | Medicine |
Subjects: | 600 Technology > 610 Medicine and health |
ISSN: | 0278-4297 |
Language: | English |
Item ID: | 111564 |
Date Deposited: | 02. Apr 2024, 07:27 |
Last Modified: | 02. Apr 2024, 07:27 |