Logo Logo
Hilfe
Hilfe
Switch Language to English

Mansour, Nabeel; Nekolla, Stephan G.; Reyes, Eliana; Angelidis, George; Georgoulias, Panagiotis; Anagnostopoulos, Constantinos; Bravo, Paco; Bruno, Isabella; Flotats, Albert; Fuentes-Ocampo, Francisco; Sciagra, Roberto; Keng, Felix; Kessler, Lukas; Papathanasiou, Maria; Soman, Prem und Rischpler, Christoph (2022): Multi-center study of inter-rater reproducibility, image quality, and diagnostic accuracy of CZT versus conventional SPECT myocardial perfusion imaging. In: Journal of Nuclear Cardiology, Bd. 30, Nr. 2: S. 528-539

Volltext auf 'Open Access LMU' nicht verfügbar.

Abstract

Background Cadmium-zinc-telluride (CZT)-based detectors exhibit higher diagnostic sensitivity in myocardial perfusion imaging (MPI) than conventional Anger-MPI for detection of coronary artery disease (CAD);however, reduced specificity and diagnostic accuracy of CZT-MPI were observed. This study aims to compare these different camera systems and to examine the degree of inter-rater reproducibility among readers with varying experience in MPI. Methods 83 patients who underwent double stress/rest examinations using both a CZT and conventional SPECT cameras within one visit were included. Anonymized and randomized MPI-images were distributed to 15 international readers using a standardized questionnaire. Subsequent coronary angiography findings of ten patients served as a reference for analysis of sensitivity and specificity. Results Image quality was significantly better in CZT-MPI with significantly lower breast attenuation (P < 0.05). CZT-MPI exhibited higher sensitivity than Anger-MPI (87.5% vs. 62.5%) and significantly reduced specificity (40% vs. 100%). Readers experienced with both camera systems had the highest inter-rater agreement indicating higher reproducibility (CZT 0.54 vs. conv. 0.49, P < 0.05). Conclusions Higher diagnostic sensitivity of CZT-MPI offers advantages in detection of CAD yet potentially of at the cost of reduced specificity, therefore it requires special training and a differentiated evaluation approach, especially for non-experienced readers with such camera systems.

Dokument bearbeiten Dokument bearbeiten