Logo Logo
Hilfe
Hilfe
Switch Language to English

Schuppert, Christopher; Kruchten, Ricarda von; Hirsch, Jochen G.; Rospleszcz, Susanne; Hoinkiss, Daniel C.; Selder, Sonja; Kohn, Alexander; Stackelberg, Oyunbileg von; Peters, Annette; Volzke, Henry; Kroncke, Thomas; Niendorf, Thoralf; Forsting, Michael; Hosten, Norbert; Hendel, Thomas; Pischon, Tobias; Jockel, Karl-Heinz; Kaaks, Rudolf; Bamberg, Fabian; Kauczor, Hans-Ulrich; Gunther, Matthias und Schlett, Christopher L. (2022): Whole-Body Magnetic Resonance Imaging in the Large Population-Based German National Cohort Study Predictive Capability of Automated Image Quality Assessment for Protocol Repetitions. In: Investigative Radiology, Bd. 57, Nr. 7: S. 478-487

Volltext auf 'Open Access LMU' nicht verfügbar.

Abstract

Background Reproducible image quality is of high relevance for large cohort studies and can be challenging for magnetic resonance imaging (MRI). Automated image quality assessment may contribute to conducting radiologic studies effectively. Purpose The aims of this study were to assess protocol repetition frequency in population-based whole-body MRI along with its effect on examination time and to examine the applicability of automated image quality assessment for predicting decision-making regarding repeated acquisitions. Materials and Methods All participants enrolled in the prospective, multicenter German National Cohort (NAKO) study who underwent whole-body MRI at 1 of 5 sites from 2014 to 2016 were included in this analysis (n = 11,347). A standardized examination program of 12 protocols was used. Acquisitions were carried out by certified radiologic technologists, who were authorized to repeat protocols based on their visual perception of image quality. Eleven image quality parameters were derived fully automatically from the acquired images, and their discrimination ability regarding baseline acquisitions and repetitions was tested. Results At least 1 protocol was repeated in 12% (n = 1359) of participants, and more than 1 protocol in 1.6% (n = 181). The repetition frequency differed across protocols (P < 0.001), imaging sites (P < 0.001), and over the study period (P < 0.001). The mean total scan time was 62.6 minutes in participants without and 67.4 minutes in participants with protocol repetitions (mean difference, 4.8 minutes;95% confidence interval, 4.5-5.2 minutes). Ten of the automatically derived image quality parameters were individually retrospectively predictive for the repetition of particular protocols;for instance, signal-to-noise ratio alone provided an area under the curve of 0.65 (P < 0.001) for repetition of the Cardio Cine SSFP SAX protocol. Combinations generally improved prediction ability, as exemplified by image sharpness plus foreground ratio yielding an area under the curve of 0.89 (P < 0.001) for repetition of the Neuro T1w 3D MPRAGE protocol, versus 0.85 (P < 0.001) and 0.68 (P < 0.001) as individual parameters. Conclusions Magnetic resonance imaging protocol repetitions were necessary in approximately 12% of scans even in the highly standardized setting of a large cohort study. Automated image quality assessment shows predictive value for the technologists' decision to perform protocol repetitions and has the potential to improve imaging efficiency.

Dokument bearbeiten Dokument bearbeiten