Logo Logo
Hilfe
Hilfe
Switch Language to English

Afat, S.; Pjontek, R.; Nikoubashman, O.; Kunz, W. G.; Brockmann, M. A.; Ridwan, H.; Wiesmann, M.; Clusmann, H.; Othman, A. E. und Hamou, H. A. (2022): Diagnostic Performance of Whole-Body Ultra-Low-Dose CT for Detection of Mechanical Ventriculoperitoneal Shunt Complications: A Retrospective Analysis. In: American Journal of Neuroradiology, Bd. 43, Nr. 11: S. 1597-1602

Volltext auf 'Open Access LMU' nicht verfügbar.

Abstract

BACKGROUND AND PURPOSE: Radiographic shunt series are still the imaging technique of choice for radiologic evaluation of VP-shunt complications. Radiographic shunt series are associated with high radiation exposure and have a low diagnostic performance. Our aim was to investigate the diagnostic performance of whole-body ultra-low-dose CT for detecting mechanical ventriculoperitoneal shunt complications. MATERIALS AND METHODS: This retrospective study included 186 patients (mean age, 54.8 years) who underwent whole-body ultra-low-dose CT (100 kV[peak];reference, 10 mAs). Two radiologists reviewed the images for the presence of ventriculoperitoneal shunt complications, image quality, and diagnostic confidence. On a 5-point Likert scale, readers scored image quality and diagnostic confidence (1 = very low, 5 = very high). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Radiation dose estimation of whole-body ultra-low-dose CT was calculated and compared with the radiation dose of a radiographic shunt series. RESULTS: 34 patients positive for VP-shunt complications were correctly identified on whole-body ultra-low-dose CT by both readers. No false-positive or-negative cases were recorded by any of the readers, yielding a sensitivity of 100% (95% CI, 87.3%-100%), a specificity of 100% (95% CI, 96.9%-100%), and perfect agreement (kappa = 1). Positive and negative predictive values were high at 100%. Shunt-specific image quality and diagnostic confidence were very high (median score, 5;range, 5-5). Interobserver agreement was substantial for image quality (kappa = 0.73) and diagnostic confidence (kappa = 0.78). The mean radiation dose of whole-body ultra-low-dose CT was significantly lower than the radiation dose of a conventional radiographic shunt series (0.67 [SD, 0.4] mSv versus 1.57 [SD, 0.6] mSv;95% CI, 0.79-1.0 mSv;P < .001). CONCLUSIONS: Whole-body ultra-low-dose CT allows detection of ventriculoperitoneal shunt complications with excellent diagnostic accuracy and diagnostic confidence. With concomitant radiation dose reduction on contemporary CT scanners, whole-body ultra-low-dose CT should be considered an alternative to the radiographic shunt series.

Dokument bearbeiten Dokument bearbeiten