Logo Logo
Hilfe
Hilfe
Switch Language to English

Nierer, Lukas; Kamp, Florian; Reiner, Michael; Corradini, Stefanie; Rabe, Moritz; Dietrich, Olaf; Parodi, Katia; Belka, Claus; Kurz, Christopher und Landry, Guillaume (2022): Evaluation of an anthropomorphic ion chamber and 3D gel dosimetry head phantom at a 0.35 T MR-linac using separate 1.5 T MR-scanners for gel readout. In: Zeitschrift für Medizinische Physik, Bd. 32, Nr. 3: S. 312-325

Volltext auf 'Open Access LMU' nicht verfügbar.

Abstract

Purpose: To date, no universally accepted technique for the evaluation of the overall dosimetric performance of hybrid integrated magnetic resonance imaging (MR) - linear accelerators (linacs) is available. We report on the suitability and reliability of a novel phantom with modular inserts for combined polymer gel (PG) and ionisation chamber (IC) measurements at a 0.35 T MR-linac. Methods: Three 3D-printed, modular head phantoms, based on real patient anatomy, were used for repeated (2 times) PG irradiations of cranial treatment plans on a 0.35 T MR-linac. The PG readout was performed on two 1.5 T diagnostic MR-scanners to reduce scanning time. The PG dose volumes were normalised to the IC dose (normalised dose N1) and to the median planning target volume dose (normalised dose N2). Linearity of the PG dose response was validated and dose profiles, centres of mass (COM) of the 95% isodoses and dose volume histograms (DVH) were compared between planned and measured dose distributions and a 3D gamma analysis was performed.Results: Dose linearity of the PG was good (R2 > 0.99 for all linear fit functions). High agreement was found between planned and measured dose volumes in the dose profiles and DVHs. The largest dose deviation was found in the intermediate dose region (mean dose deviation 0.2 Gy;5.6%). A mean COM offset of 1.2 mm indicated high spatial accuracy. Mean 3D gamma passing rates (2%, 2 mm) of 83.3% for N1 and 91.6% for N2 dose distributions were determined. When comparing repeated PG measurements to each other, a mean gamma passing rate of 95.7% was found.Conclusion: The new modular phantom was found practical for use at a 0.35 T MR-linac. In contrast to the high dose region, larger mean deviations were found in the mid dose range. The PG measurements showed high reproducibility. The MR-linac performed well in a non-adaptive setting in terms of spatial and dosimetric accuracy.

Dokument bearbeiten Dokument bearbeiten