Fanelli, Flaminia; Cantu, Marco; Temchenko, Anastasia; Mezzullo, Marco; Lindner, Johanna M.; Peitzsch, Mirko; Hawley, James M.; Bruce, Stephen; Binz, Pierre-Alain; Ackermans, Mariette T.; Heijboer, Annemieke C.; Ouweland, Jody van den; Koeppl, Daniel; Nardi, Elena; MacKenzie, Finlay; Rauh, Manfred; Eisenhofer, Graeme; Keevil, Brian G.; Vogeser, Michael und Pagotto, Uberto (2022): Report from the HarmoSter study: impact of calibration on comparability of LC-MS/MS measurement of circulating cortisol, 17OH-progesterone and aldosterone. In: Clinical Chemistry and Laboratory Medicine, Bd. 60, Nr. 5: S. 726-739

Volltext auf 'Open Access LMU' nicht verfügbar.

Abstract

Objectives Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is recommended for measuring circulating steroids. However, assays display technical heterogeneity. So far, reproducibility of corticosteroid LC-MS/MS measurements has received scant attention. The aim of the study was to compare LC-MS/MS measurements of cortisol, 17OH-progesterone and aldosterone from nine European centers and assess performance according to external quality assessment (EQA) materials and calibration. Methods Seventy-eight patient samples, EQA materials and two commercial calibration sets were measured twice by laboratory-specific procedures. Results were obtained by in-house (CAL1) and external calibrations (CAL2 and CAL3). We evaluated intra and inter-laboratory imprecision, correlation and agreement in patient samples, and trueness, bias and commutability in EQA materials. Results Using CAL1, intra-laboratory CVs ranged between 2.8-7.4%, 4.4-18.0% and 5.2-22.2%, for cortisol, 17OH-progesterone and aldosterone, respectively. Trueness and bias in EQA materials were mostly acceptable, however, inappropriate commutability and target value assignment were highlighted in some cases. CAL2 showed suboptimal accuracy. Median inter-laboratory CVs for cortisol, 17OH-progesterone and aldosterone were 4.9, 11.8 and 13.8% with CAL1 and 3.6, 10.3 and 8.6% with CAL3 (all p<0.001), respectively. Using CAL1, median bias vs. all laboratory-medians ranged from -6.6 to 6.9%, -17.2 to 7.8% and -12.0 to 16.8% for cortisol, 17OH-progesterone and aldosterone, respectively. Regression lines significantly deviated from the best fit for most laboratories. Using CAL3 improved cortisol and 17OH-progesterone between-method bias and correlation. Conclusions Intra-laboratory imprecision and performance with EQA materials were variable. Inter-laboratory performance was mostly within specifications. Although residual variability persists, adopting common traceable calibrators and RMP-determined EQA materials is beneficial for standardization of LC-MS/MS steroid measurements.

Dokument bearbeiten Dokument bearbeiten