Nef, Holger; Wiebe, Jens; Achenbach, Stefan; Münzel, Thomas; Naber, Christoph; Richardt, Gert; Mehilli, Julinda; Wöhrle, Jochen; Neumann, Till; Biermann, Janine; Zahn, Ralf; Kastner, Johannes; Schmermund, Axel; Pfannebecker, Thomas; Schneider, Steffen; Limbourg, Tobias und Hamm, Christian W. (2016): Evaluation of the short- and long-term safety and therapy outcomes of the everolimus-eluting bioresorbable vascular scaffold system in patients with coronary artery stenosis: Rationale and design of the German-Austrian ABSORB RegIstRy (GABI-R). In: Cardiovascular Revascularization Medicine, Bd. 17, Nr. 1: S. 34-37

Volltext auf 'Open Access LMU' nicht verfügbar.

Abstract

Background: Third-generation drug-eluting metal stents are the gold standard for treatment of coronary artery disease. The permanent metallic caging of the vessel, however, can result in limited vasomotion, chronic inflammation, and late expansive remodeling, conditions that can lead to late and very late stent thrombosis. The development of bioresorbable scaffolds (BRSs) promises advantages over metal stents due to complete biodegradation within 2-4 years. Theoretically, since vessel scaffolding is temporary and no permanent implant remains in the vessel, BRSs, as opposed to metal stents, once degraded would no longer be potential triggers for stent-related adverse events or side effects. Methods/design: The short-and long-term outcome after implantation of an everolimus-eluting, poly-L-lactic acid-based bioresorbable scaffold system (ABSORB, Abbott Vascular, Santa Clara, CA, USA) in the world-wide greatest all-comers cohort will be evaluated in the prospective, non-interventional, multicenter German-Austrian ABSORB RegIstRy (GABI-R). GABI-R will include over 5000 patients from about 100 study sites in Austria and Germany. Safety endpoints such as cardiac death, myocardial infarction, and clinically driven percutaneous or surgical target lesion and vessel revascularization will be evaluated during hospitalization and in the follow-up period (minimum of 5 years). Conclusion: Although two randomized controlled trials and several registries have documented safety and efficacy as well as non-inferiority of this everolimus-eluting ABSORB device compared with drug-eluting metal stents, the current knowledge regarding clinical application, treatment success, and long-term safety of using this BRS in daily routine is limited. Thus, the goal of GABI-R is to address this lack of information. (C) 2015 ELSEVIER. All rights reserved.

Dokument bearbeiten Dokument bearbeiten