Logo Logo
Hilfe
Hilfe
Switch Language to English

Eschbach, Ralf Stefan; Clevert, Dirk-André; Hirner-Eppeneder, Heidrun; Ingrisch, Michael; Moser, Matthias; Schuster, Jessica; Tadros, Dina; Schneider, Moritz; Kazmierczak, Philipp Maximilian; Reiser, Maximilian und Cyran, Clemens C. (2017): Contrast-Enhanced Ultrasound with VEGFR2-Targeted Microbubbles for Monitoring Regorafenib Therapy Effects in Experimental Colorectal Adenocarcinomas in Rats with DCE-MRI and Immunohistochemical Validation.
In: PLOS One 12(1), e0169323 [PDF, 2MB]

[thumbnail of journal.pone.0169323.pdf]
Vorschau
Download (2MB)

Abstract

Objectives To investigate contrast-enhanced ultrasound (CEUS) with VEGFR2-targeted microbubbles for monitoring therapy effects of regorafenib on experimental colon carcinomas in rats with correlation to dynamic contrast-enhanced MRI (DCE-MRI) and immunohistochemistry. Materials and Methods: Human colorectal adenocarcinoma xenografts (HT-29) were implanted subcutaneously in n =21 (n = 11 therapy group;n = 10 control group) female athymic nude rats (Hsd: RH-Foxn1 (mu)). Animals were imaged at baseline and after a one-week daily treatment with regorafenib or a placebo (10 mg/kg bodyweight), using CEUS with VEGFR2-targeted microbubbles and DCE-MRI. In CEUS tumor perfusion was assessed during an early vascular phase (wash-in area under the curve = WiAUC) and VEGFR2-specific binding during a late molecular phase (signal intensity after 8 (SI8min) and 10 minutes (SI10min)), using a conventional 15L8 linear transducer (transmit frequency 7 MHz, dynamic range 80 dB, depth 25 mm). In DCE-MRI functional parameters plasma flow (PF) and plasma volume (PV) were quantified. For validation purposes, CEUS parameters were correlated with DCE-MRI parameters and immunohistochemical VEGFR2, CD31, Ki-67 and TUNEL stainings. Results: CEUS perfusion parameter WiAUC decreased significantly (116,989 +/- 77,048 a.u. to 30,076 +/- 27,095a.u.;p = 0.005) under therapy with no significant changes (133,932 +/- 65,960 a.u. to 84,316 +/- 74,144 a.u.;p = 0.093) in the control group. In the therapy group, the amount of bound microbubbles in the late phase was significantly lower in the therapy than in the control group on day 7 (SI8min: 283 +/- 191 vs. 802 +/- 460 a.u.;p = 0.006);SI10min: 226 +/- 149 vs. 645 +/- 461 a.u.;p = 0.009). PF and PV decreased significantly (PF: 147 +/- 58 mL/100 mL/min to 71 +/- 15 mL/100 mL/min;p = 0.003;PV: 13 +/- 3% to 9 +/- 4%;p = 0.040) in the therapy group. Immunohistochemistry revealed significantly fewer VEGFR2 (7.2 +/- 1.8 vs. 17.8 +/- 4.6;p < 0.001), CD31 (8.1 +/- 3.0 vs. 20.8 +/- 5.7;p < 0.001) and Ki-67 (318.7 +/- 94.0 vs. 468.0 +/- 133.8;p = 0.004) and significantly more TUNEL (672.7 +/- 194.0 vs. 357.6 +/- 192.0;p = 0.003) positive cells in the therapy group. CEUS parameters showed significant (p < 0.05) correlations to DCE-MRI parameters and immunohistochemistry. Conclusions CEUS with VEGFR2-targeted microbubbles allowed for monitoring regorafenib functional and molecular therapy effects on experimental colorectal adenocarcinomas with a significant decline of CEUS and DCE-MRI perfusion parameters as well as a significant reduction of specifically bound microbubbles under therapy, consistent with a reduced expression of VEGFR2.

Dokument bearbeiten Dokument bearbeiten