Kern, Christoph; Priglinger, Siegfried; Mackert, Marc J. (2020): Trübung der Intraokularlinse nach kombinierter Katarakt- und minimal-invasiver Glaukomchirurgie (MIGS). In: Ophthalmologe, Vol. 118, No. 7: pp. 724-727
Full text not available from 'Open Access LMU'.

Abstract

A visual deterioration due to opacification of the intraocular lens was observed 3 weeks after uncomplicated combined minimally invasive glaucoma and cataract surgery. Due to the patient's failure to apply the prescribed postoperative local anti-inflammatory eyedrops, homogeneous fibrin coating on the anterior surface of the lens occurred, as well as early scarring of the filtering bleb. We performed needling with 5-fluorouracil and lens polishing with the Nd:YAG laser to achieve sufficient pressure control and vision improvement.