Chacon, Andrew; James, Benjamin; Tran, Linh; Guatelli, Susanna; Chartier, Lachlan; Prokopvich, Dale; Franklin, Daniel R.; Mohammadi, Akram; Nishikido, Fumihiko; Iwao, Yuma; Akamatsu, Go; Takyu, Sodai; Tashima, Hideaki; Yamaya, Taiga; Parodi, Katia; Rosenfeld, Anatoly und Safavi-Naeini, Mitra (2020): Experimental investigation of the characteristics of radioactive beams for heavy ion therapy. In: Medical Physics, Bd. 47, Nr. 7: S. 3123-3132

Volltext auf 'Open Access LMU' nicht verfügbar.

Abstract

Purpose: This work has two related objectives. The first is to estimate the relative biological effectiveness of two radioactive heavy ion beams based on experimental measurements, and compare these to the relative biological effectiveness of corresponding stable isotopes to determine whether they are therapeutically equivalent. The second aim is to quantitatively compare the quality of images acquired postirradiation using an in-beam whole-body positron emission tomography scanner for range verification quality assurance. Methods: The energy deposited by monoenergetic beams of 11C at 350 MeV/u, 15O at 250 MeV/u, 12C at 350 MeV/u, and 16O at 430 MeV/u was measured using a cruciform transmission ionization chamber in a water phantom at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Dose-mean lineal energy was measured at various depths along the path of each beam in a water phantom using a silicon-on-insulator mushroom microdosimeter. Using the modified microdosimetric kinetic model, the relative biological effectiveness at 10% survival fraction of the radioactive ion beams was evaluated and compared to that of the corresponding stable ions along the path of the beam. Finally, the postirradiation distributions of positron annihilations resulting from the decay of positron-emitting nuclei were measured for each beam in a gelatin phantom using the in-beam whole-body positron emission tomography scanner at HIMAC. The depth of maximum positron-annihilation density was compared with the depth of maximum dose deposition and the signal-to-Background: ratios were calculated and compared for images acquired over 5 and 20 min postirradiation of the phantom. Results: In the entrance region, the hboxRBE10 was 1.2 +/- 0.1 for both 11C and 12C beams, while for 15O and 16O it was 1.4 +/- 0.1 and 1.3 +/- 0.1, respectively. At the Bragg peak, the RBE10 was 2.7 +/- 0.4 for 11C and 2.9 +/- 0.4 for 12C, while for 15O and 16O it was 2.7 +/- 0.4 and 2.8 +/- 0.4, respectively. In the tail region, RBE10 could only be evaluated for carbon;the RBE10 was 1.6 +/- 0.2 and 1.5 +/- 0.1 for 11C and 12C, respectively. Positron emission tomography images obtained from gelatin targets irradiated by radioactive ion beams exhibit markedly improved signal-to-Background: ratios compared to those obtained from targets irradiated by nonradioactive ion beams, with 5-fold and 11-fold increases in the ratios calculated for the 15O and 11C images compared with the values obtained for 16O and 12C, respectively. The difference between the depth of maximum dose and the depth of maximum positron annihilation density is 2.4 +/- 0.8 mm for 11C, compared to -5.6 +/- 0.8 mm for 12C and 0.9 +/- 0.8 mm for 15O vs -6.6 +/- 0.8 mm for 16O. Conclusions: The RBE10 values for 11C and 15O were found to be within the 95% confidence interval of the RBEs estimated for their corresponding stable isotopes across each of the regions in which it was evaluated. Furthermore, for a given dose, 11C and 15O beams produce much better quality images for range verification compared with 12C and 16O, in particular with regard to estimating the location of the Bragg peak.

Dokument bearbeiten Dokument bearbeiten